Mockett's Irrigation Services

Water Resource Specialists

This Aerator sets new standards in the removal of iron from water. It is particularly suited for use where large volumes of water require treating for farms, horticulture blocks, industrial users, households and many more applications

 

This unit will give years of service and is made from long lasting fibreglass.

How It Works

The water to be treated passes through a series of spray nozzles at sufficient pressure in the top compartment to be atomised. This exposes the iron to the oxygen in the air, which then allows it to be precipitate out of the water. The water then passes through a special sand filtering medium in the bottom compartment leaving the iron sludge in the top layer - this is washed out by backflushing at regular intervals.

 

Nozzle And Pressure Selection

From the chart below the pressure and quantity of water to be treated can be selected and the required number of nozzles then arrived at. This then determines the size of the unit required.

The optimum pressure is within the 10 - 20 m Head range

Some pump performances are referred to in g.p.h. therefore two nozzles at 38 l.p.m. = 500 g.p.h

               
      16 (110) 32 (221) 48 (332)   p.s.i. (kPa)  
     

10

20 30   m.Head  
Number of Nozzles 2

21

30 38   l.p.m.  
per Unit   4

42

60 76   l.p.m.  
    6 63 90 114   l.p.m.  
    8 84 120     l.p.m.  
               

Backwashing Requirements

This will vary according to the amount of iron to be removed. The golden rule should be for short periods, at frequent intervals. The following chart is a guide only an should be used to assist in selecting an approximate time cycle which should then be adjusted by experience. If the water from the waste pipe is very rusty you should decrease the intervals until it appears at the start to be only a creamy colour, The time for the water to clear should be a maximum of five minutes.

             
    p.p.m. IRON CONTENT OF WATER  
Total quantity of   2.5 5 7.5 10  
treated water Ltrs   175,000 150,000 125,000 100,000  
             
             

 

To backflush unit use a minimum pump capacity of 410 l.p.m. at a head of 6m capacity or equivalent.